BackForward Variable: Relative humidity

Definition
Full name Relative humidity
Definition 3D field of relative humidity in the atmosphere. Relative humidity is the ratio of the amount of atmospheric moisture present relative to the amount that would be present if the air were saturated with respct to water or ice to be specified in the metadata
Measuring Units % Uncertainty Units %
Horizontal Res Units km Vertical Res Units km
Stability Units % (Stability /decade)

 

Comment:
Last modified: 2019-09-25
Applied in OSCAR/Space Gap Analysis: No
Classification
  • Domain: Atmosphere
    • Sub-domain: Basic atmospheric
      • Variable: Relative humidity
        • Measured in Layers:
          • UTLS
          • FT
          • PBL
  • Cross-cutting themes:

Requirements defined for Relative humidity  (3)

This tables shows all related requirements. For more operations/filtering, please consult the full list of Requirements
Note: In reading the values, goal is marked blue, breakthrough green, threshold orange
Application-dependent Technical Priority (ATP) Magenta and Relative priority of the attributes Red

Id Variable Layer App Area ATP Uncertainty Layer/s Quality Coverage Quality Stability / decade Hor Res Ver Res Obs Cyc Timeliness Coverage Conf Level Val Date Source General Comment Application Area Comment Horizontal Coverage Comment Observation Comment Performance Comment
789 Relative humidity PBL 2.5 Atmospheric Climate Monitoring 0.5 0.1 %
0.5 %
1 %
0.5
0.1 %
0.5 %
1 %
0.5
15 km
100 km
500 km
0.5
0.001 km
0.01 km
0.1 km
0.5
30 min
6 h
12 h
0.5
60 min
5 d
30 d
0.5
Global firm 2023-05-09 GCOS-245: The 2022 ECVs Requirements (GCOS-245) Requirements for uncertainty are specified at 2-sigma. Units for uncertainty and stability are %RH GOAL for temporal resolution is sub-hourly
790 Relative humidity UTLS 2.5 Atmospheric Climate Monitoring 0.5 0.5 %
1 %
2 %
0.5
0.5 %
0.5 %
2 %
0.5
15 km
100 km
500 km
0.5
0.01 km
0.1 km
0.25 km
0.5
3 h
6 h
24 h
0.5
60 min
5 d
30 d
0.5
Global firm 2023-05-09 GCOS-245: The 2022 ECVs Requirements (GCOS-245) Requirements for uncertainty are specified at 2-sigma. Units for uncertainty and stability are %RH Goal for stability is < 0.5%RH
997 Relative humidity FT 2.5 Atmospheric Climate Monitoring 0.5 0.1 %
0.5 %
1 %
0.5
0.1 %
0.5 %
1 %
0.5
15 km
100 km
1000 km
0.5
0.01 km
0.1 km
1 km
0.5
30 min
6 h
12 h
0.5
60 min
5 d
30 d
0.5
Global firm 2023-05-09 GCOS-245: The 2022 ECVs Requirements (GCOS-245) Requirements for uncertainty are specified at 2-sigma. Units for uncertainty and stability are %RH Goal for temporal resolution is Sub-hourly