Requirement #115 

Values

For variable: Integrated Water Vapour (IWV)

In application: Climate-AOPC (deprecated)

Application-dependent Technical Priority: 0.0

Goal Breakthrough Threshold Priority
Uncertainty 1 kg.m-2 1.4 kg.m-2 3 kg.m-2
Layer/s Quality
Coverage Quality
Stability/decade (if applicable)
Horizontal Resolution 10 km 25 km 200 km
Vertical Resolution
Observing Cycle 3 h 4 h 6 h
Timeliness 7 d 14 d 60 d

 

Validated: 7/19/07 Source: AOPC
General Comment: Confidence: reasonable
Def: :Not firm, but based on a strong heritage of experiments with similar data
Application Area Comment: Horizontal Coverage Comment:
Observation Comment: Performance Comment:
Specifications
  • Domain: Atmosphere